SECCO analyzes the important points of installing induction automatic doors

2015-5-28 10:25:49 Article source: http://junpairhy.com/click :
The installation steps of the induction automatic door are as follows:
First of all, when installing the aluminum alloy box beam, pay attention to keeping it horizontal. If it is not horizontal, it will cause uneven force when the door is walking, which will reduce the life of the machine.
First, the door hanging installation:
a. Use the attached door body hanging bolt assembly to install the hanger device to the designated position on the door body.
b. During installation, the center of the pulley of the hanger device and the door should be parallel. If they are not parallel, the life of the pulley will be shortened.
C. Hang the pulley of the hanging device on the power beam.
d. During installation, please do not hurt other components in the power beam and guide rails, otherwise it will cause component failure or pulley life, noise, abnormal sound, etc.
Installation of limit devices:
1) Loosen the stopper mounting bolts.
2) Move the door body to determine the door opening and closing position and the position of the stopper.
3) When setting the position of the stopper device, make the suspension device stop after touching the rubber pad of the stopper.
Third, the height of the door and the adjustment of the gap:
(1) Loosen the fixing hanger nut.
(2) Check the resistance when walking and whether the door is heavy when moving.
4. If there is a friction sound, confirm the following:
1.Whether the hanging is fixed on the door body and rubbing it * Whether there is friction between the door body and the door frame * Whether the hanging device has friction with the power beam
2. The height of the door fan and the ground is generally kept at 10mm. The gap between the moving fan and the fixed fan is 5mm.
V. Adjustment of belt tension:
(1) Pull the tensioning wheel device to the left to keep the belt tight, and then tighten the four pressure plate bolts.
(2) Loosen the four adjustments and adjust the belt tension with the fixing bolts.
Installation of ground wheels
When installing the center position of the ground wheel, add 5mm to the half of the width of the door fan. (The premise is that there is a slideway in the bottom of the moving fan. If there is no slideway directly covering the decorative panel, the internal space distance should be considered, and it should be calculated according to the actual situation.) After installation, please ensure that the upper and lower gaps of the door body are the same to avoid long-term damage Ground wheel. This article is excerpted from Hefei induction door : junpairhy.com